◆ DSP (Digital signal processors) control
◆ Output Power Factor is 1.0
◆ Variety output voltage configuration,single phase 220V/240V or dual phase 110V/115V/120V
◆ Galvanic isolation transformer between in AC input and output in all operating mode
◆ Active input power factor correction, input power factor>0.99
◆ Three level inverter technology,lower harmonic,higher efficiency
◆ Wide input voltage range 90V~300V and frequency range 40~70Hz
◆ Generator compatible
◆ Cold start function
◆ Remote on off (ROO) function (optional)
◆ Economic operation mode (ECO)
◆ 50Hz/60Hz Frequency auto sensing
◆ Frequency converter mode: 50Hz input / 60Hz output or 60Hz input / 50Hz output
◆ Communications:RS232(standard), USB / MODBUS / RS485 / SNMP / AS400 card (optional)
◆ Reliable design, made with strong Glass fiber base (FR4) double side PCB, Well designed ventilation and conformal coating
We were established in 2015 , have two producing bases , 5 production line and monthly produce about 80,000 pieces.
Our ODM & OEM production is strictly based on the IS09001 and service customers in need.
REO is a one top power solution provider and warmly welcome to be our distributor and partner
Accept Deeply Customized Products
Model | Warrior 6K | Warrior 6KL | Warrior 10K | Warrior 10KL |
Capacity | 6KVA/6KW | 10KVA/10KW | ||
AC INPUT | ||||
Wiring | 1 phase 3 wires ( L / N+PE) or biphase 3 wires (L1+L2+PE) | |||
Rated Voltage | 208/220/230/240VAC | |||
Rated Frequency | 50Hz/60HZ | |||
Voltage Range | 110~285VAC±5VAC | |||
Frequency Range | (40~70)±0.5Hz | |||
Input Power Factor | >0.99 | |||
Bypass Voltage Range | 180~265VAC | |||
BATTERY & CHARGER | ||||
Rated Battery Voltage | 192VDC Internal (240VDC optional) |
192/240VDC External |
192VDC Internal (240VDC optional) |
192/240VDC External |
Battery Capacity | 12V/7AH x 16Pcs | External battery depends | 12V/7AH x 16pcs | External battery depends |
Backup Time | >6mins @ half load | >6mins @ half load | ||
Charging Current | Standard model with internal battery : 2A/4A (settable by LCD) Long backup time model :4A |
|||
AC OUTPUT | ||||
Wiring | 1 phase 3 wires ( L / N+PE) or biphase 5 wires (L1/N1+L2/N2 +PE) | |||
Output Voltage | High voltage 208/220/230/240VAC ; Low voltage 110/120VAC | |||
Output Frequency | 50/60±4Hz (Synchronized range); 50/60Hz±0.1 (Battery mode) | |||
Voltage Regulation | +/-3% | |||
Waveform | Pure sine wave | |||
Distortion | <2%(Linear load) | |||
(THDV%) | <7%(Non-Linear load) | |||
Output Power Factor | 1.0 | |||
Overload Capability | 10min@105%~125%; 60s@125%~150%; 0.5S@>150% | |||
Transfer Time | Line mode – battery mode :0ms | |||
HMI | ||||
LCD Display | Input mains voltage, frequency, load level, operation mode, health status | |||
Standards Communication Interface | (1) RS232 port | |||
Optional | (2) EPO / ROO port (3) Intelligent slot (4) USB port (5) NMC Card: Support remote monitor the UPS via Smart phone APP, web page,PC monitor software , support server / NAS shutdown (6) CMC MODBUS card (7) AS400 Relay card (8) SNMP card |
|||
OPERATING ENVIRONMENT | ||||
Temperature Range | -10~50oC | |||
Relative Humidity | 0-98% (Non-condensing) | |||
Acoustics Noise | <55dB @ 1 meters | |||
PHYSICAL PARAMETERS | ||||
Dimension WxDxH (mm) |
299x698x700 | |||
N.W (kg) | 95 | 61.8 | 103 | 72.2 |
• Product specifications are subject to change without prior notice
• Ambient temperature>30°C, output power factor is 0.9
• Model with”L” mean long back up time model, without “L” mean standard model
Accept Deeply Customized Products
Model | Warrior 10K | Warrior 10KL | Warrior 15K | Warrior 15KL | Warrior 20K | Warrior 20KL |
Capacity | 10KVA/10KW | 15KVA/15KW | 20KVA/20KW | |||
Topology | Double conversion online UPS with two phase galvanic isolation output transformer | |||||
AC INPUT | ||||||
Wiring | Biphase 3 wires (L1+L2+PE)-220V or 1phase 3 wires ( L+N+PE) -220V or 3phase 5 wires (L1, L2, L3, N+PE)-380V | |||||
Rated Voltage | 208/220/230/240VAC | |||||
Rated Frequency | 50Hz/60Hz | |||||
Voltage Range | 110~285VAC±5VAC | |||||
Frequency Range | (40~70)±0.5Hz | |||||
Input Power Factor | >0.99 | |||||
Bypass Voltage Range | 180~265VAC | |||||
BATTERY & CHARGER | ||||||
Rated Battery Voltage | 192VDC Internal |
192VDC/240VDC External | 192VDC Internal |
192VDC/240VDC External | 192VDC Internal |
192VDC/240VDC External |
Battery Capacity | 12V/7AH x 16pcs | External battery depends | 12V/7AH x 32pcs | External battery depends | 12V/9AH x 32pcs | External battery depends |
Backup Time | >6mins @ half load | >3mins @ half Load | >2mins @ half load | |||
Charging Current | Standard model with internal battery, 10K: 2A/4A (settable by LCD) ; 15K~20K:4A Long backup time model: 4A/8A(optional) |
|||||
Optional Configuration to Order | 1. Battery capacity 7AH/9AH 2. Battery quantity 16pcs or 32pcs |
|||||
AC OUTPUT | ||||||
Wiring | 1 phase 3 wires ( L/N+PE) or biphase 5 wires(L1/N1+L2/N2+PE) | |||||
Output Voltage | High voltage 208/220/230/240VAC ; Low voltage 110/120VAC | |||||
Output Frequency | 50/60±4Hz (Synchronized range); 50/60Hz±0.1 (Battery mode) | |||||
Voltage Regulation | ±3% | |||||
Waveform | Pure sine wave | |||||
Distortion (THDV%) | <2% (Linear load) ; <7% (Non-Linear load) | |||||
Output Power Factor | 1.0 | |||||
Overload Capability | 10min@105%~125% ; 60s@125%~150% ; 0.5S@>150% | |||||
Transfer Time | Line mode – Battery mode : 0ms | |||||
HMI | ||||||
LCD Display | Input mains voltage, frequency, load level, operation mode, health status | |||||
Standards Communication Interface | (1) RS232 port | |||||
Optional | (2) EPO / ROO port (3) Intelligent slot (4) USB port (5) NMC Card: Support remote monitor the UPS via Smart phone APP, web page,PC monitor software , support server / NAS shutdown (6) CMC MODBUS card (7) AS400 Relay card (8) SNMP card |
|||||
ENVIRONMENT | ||||||
Temperature Range | -10~50oC | |||||
Relative Humidity | 0-98%(Non-condensing) | |||||
Acoustics Noise | <55dB @ 1 meters | |||||
PHYSICAL | ||||||
Dimension WxDxH (mm) |
296x700x720 | 299x698x700 | 400x860x844 | 296x700x720 | 400x860x844 | 296x700x720 |
N.W (kg) | 105 | 72.9 | 195.6 | 109 | 199 | 111 |
• Product specifications are subject to change without prior notice
• Ambient temperature>30°C, output power factor is 0.9
• Model with”L” mean long back up time model, without “L” mean standard model