◆ Output power factor 1.0
◆ DSP (Digital signal processors) control
◆ Three level inverter topology, supports with extensive range of load
◆ Active input power factor correction, input power factor> 0.99
◆ Wide input voltage range 90V~300V and frequency range 40~70Hz
◆ Generator compatible
◆ Long battery lifecycle, more than 2000
◆ Remote on off (ROO) function (optional)
◆ Cold start & Economic operation mode (ECO)
◆ 50Hz/60Hz Frequency auto sensing
◆ Frequency converter mode: 50Hz input / 60Hz output or 60Hz input / 50Hz output
◆ Li-ion battery provide up to 3x backup time, comparing with regular Lead-acid UPS product
◆ Dry contact interface for BMS dominant control
◆ Incorporated MODBUS (RS485) interface with BMS, to achieve precise battery information (voltage/soc/soh etc.)
◆ Li-ion Battery Charger : Constant current , constant voltage, floating, turn-off 4 state charger for Li-ion battery, open to customize the logical behavior for customer- specified battery pack
We were established in 2015 , have two producing bases , 5 production line and monthly produce about 80,000 pieces.
Our ODM & OEM production is strictly based on the IS09001 and service customers in need.
REO is a one top power solution provider and warmly welcome to be our distributor and partner
Accept Deeply Customized Products
Tower Model | Nova 1K-Li | Nova 1KL-Li | Nova 2K-Li | Nova 2KL-Li | Nova 3K-Li | Nova 3KL-Li |
Rack Model | Nova 1KR-Li | Nova 1KRL-Li | Nova 2KR-Li | Nova 2KRL-Li | Nova 3KR-Li | Nova 3KRL-Li |
Capacity | 1KVA/1KW | 2KVA/2KW | 3KVA/3KW | |||
Phase | Single phase input single phase output | |||||
AC INPUT | ||||||
Wiring | L/N+PE | |||||
Rated Voltage | 208/220/230/240VAC | |||||
Voltage Range | 90~300VAC | |||||
Frequency Range | 40Hz~70Hz | |||||
Input Power Factor | ≥0.99 | |||||
AC OUTPUT | ||||||
Wiring | L/N+PE | |||||
Output Voltage | 208/220/230/240VAC | |||||
Voltage Regulation | ±1% | |||||
Output Frequency | 50/60±4Hz(Synchronized range); 50/60Hz±0.1(Battery mode) | |||||
Waveform | Pure sine wave | |||||
Power Factor | 1.0 | |||||
Distortion (THDV%) | <2%(Linear Load) ;<8%(Non-Linear Load) | |||||
Overload Capability | 100%~105% continuous; 60Sec.@105%~130% rated load; 10Sec.@130%~150% rated load; 0.3Sec.@>150% rated load. | |||||
EFFICIENCY | ||||||
Line Mode | 90% | 91% | 92% | |||
Battery Mode | 87% | 88% | 89% | |||
ECO mode | 95% | |||||
BATTERY & CHARGER | ||||||
Rated Battery Voltage | 51.2/48VDC(default for 16cell of LiFePO4 ) | |||||
Battery Capacity | 615WH | External battery depends | 920WH | External battery depends | 1250WH | External battery depends |
Backup Time | >30mins @ full load | >20mins @ full load | >20mins @ full load | |||
Backup Time 2 (External Battery Module) | 51.2V 50AH-150mins 51.2V 100AH-300mins @ Full Load |
51.2V 50AH-75mins 51.2V 100AH-150mins @ Full Load |
51.2V 50AH-50mins 51.2V 100AH-100mins @ Full Load |
|||
Charging Current | 1~3K standard model with internal battery:4A 1~2K long backup time model: 4A, 8A/12A (optional) 3K long backup time model: 6A, 12A/16A (optional) |
|||||
Charging Voltage | 56.8V(default for 16cell of LiFePO4 ) / customized according to battery request | |||||
Charger Behavior & Protection | CC. CV. floating. turn-off 4 states 3 over voltage protection loop, preserve interface for over temperature/over pressure switch off interface |
|||||
HMI | ||||||
LED Display | Mains / battery status, load level, battery level, operation mode | |||||
LCD Display with LED Indicator | Input mains voltage, frequency, load level, operation mode, health status, battery SOC | |||||
Standards Communication | (1) RS232 port / USB port (2) Dry contact interface for BMS control (3) Modbus for BMS interface |
|||||
Optional | (4) NetWork Card: Support SNMP/TCP/IP for remote monitoring the UPS via Smart Phone APP, Web page, PC Monitor Software , Support Server / NAS shutdown (5) RS485-Modbus Card, LAN (TCP IP)-Modbus Card (6) Mini AS400 Relay Card (7) SNMP card |
|||||
ENVIRONMNET | ||||||
Temperature range | -10~50oC | |||||
Relative Humidity | 0-98%(Non-condensing) | |||||
Acoustics Noise | <55dB @ 1 meters | |||||
PHYSICAL | ||||||
Tower Dimension WxDxH (mm) |
1K-Li: 190x442x323 | 2K-Li: 190x442x323 | 3K-Li: 190x442x323 | |||
1KL-Li: 190x380x323 | 2KL-Li: 190x380x323 | 3KL-Li: 190x380x323 | ||||
Rack Dimension WxDxH (mm) |
1KR-Li: 440x400x88 (2U) | 2KR-Li: 440x500x88 (2U) | 3KR-Li: 440x612x88 (2U) | |||
1KRL-Li: 440x400x88 (2U) | 2KRL-Li: 440x400x88 (2U) | 3KRL-Li: 440x400x88 (2U) | ||||
Tower N.W (kg) | 14.8 | 8.5 | 16 | 8.6 | 20.4 | 9.3 |
Rack N.W (kg) | 13.6 | 8 | 18.5 | 8.4 | 20.9 | 8.9 |
• Product specifications are subject to change without prior notice
• Ambient temperature>30°C, output power factor is 0.9
• Model with”L” mean long back up time model, without “L” mean standard model
Accept Deeply Customized Products
Tower Model | Nova 6KL-Li | Nova 10KL-Li |
Rack Model | Nova 6KRL-Li | Nova 10KRL-Li |
Capacity | 6KVA/6KW | 10KVA/10KW |
AC INPUT | ||
Input System | Single phase (L/N+PE) | |
Nominal Voltage | 208/220/230/240VAC | |
Frequency | 50/60Hz | |
Voltage Range | 90~300VAC | |
Frequency Range | (40~70)±0.5Hz | |
Input Power Factor | >0.99 | |
BATTERY INPUT | ||
Rated Battery Voltage | 51.2/48VDC(default for 16cell of LiFePO4 ) | |
Battery Capacity | External | |
Charger Behavior & Protection | CC. CV. floating. turn-off 4 states 3 over voltage protection loop, preserve interface for over temperature/over pressure switch off interface |
|
Charging Current | 30A | |
AC OUTPUT | ||
Output Wiring System | Single phase (L/N+PE) | |
Inverter Output Voltage | 208/220/230/240VAC±1% | |
Waveform | Pure sine wave | |
Power Factor | 1.0 | |
Harmonic Distortion | THD<2% (linear load) ; THD<7% (non-linear load) | |
Output Frequency | 50/60±4Hz(Synchronized range); 50/60Hz±0.1(Battery mode) | |
Overload Capability | 100%~105% continuous; 60Sec.@105%~130% rated load; 10Sec.@130%~150% rated load; 0.3Sec.@>150% rated load. |
|
Transfer Time | Line mode <-> Battery mode : 0ms | |
EFFICIENCY | ||
Line Mode | >92% | >93% |
Battery Mode | >90% | |
ECO Mode | 97% | |
OTHERS | ||
Standards Communication | (1) RS232 port / USB port (2) Dry contact interface for BMS control (3) Modbus For BMS interface |
|
Optional | (4) NetWork Card: Support SNMP/TCP/IP for remote monitoring the UPS via Smart Phone APP, Web page, PC Monitor Software , Support Server / NAS shutdown (5) RS485-Modbus Card, LAN (TCP IP)-Modbus Card (6) Mini AS400 Relay Card (7) SNMP card |
|
Alarm Function | AC/DC input under abnormal, overload condition and inverter problems | |
Protection Function | AC input or output above or below the range of voltage, overload, over temperature and short circuit protection | |
ENVIRONMENT | ||
Temperature Range | -10~50oC | |
Relative Humidity | 0-98%(Non-condensing) | |
Acoustics Noise | <55dB @ 1 meters | |
PHYSICAL | ||
Tower Dimension WxDxH (mm) |
190x378x318 | 190x546x340 |
Rack Dimension WxDxH (mm) |
440x500x88(2U) | 440x500x88(2U) |
Tower N.W (kg) | 14.8 | 16 |
Rack N.W (kg) | 11.5 | 13.5 |
• Product specifications are subject to change without prior notice
• Ambient temperature>30°C, output power factor is 0.9
• Model with”L” mean long back up time model, without “L” mean standard model